Kohler generator code Over Crank
High severity — The controller made three unsuccessful attempts to start the engine and locked out with an Over Crank shutdown fault.
Applies to: Kohler residential standby generators with an RDC2 or DC2 controller
What it means
Three tries and it gives up — that's the entire logic behind this fault. The RDC2 or DC2 controller cranks the engine, waits for a run signal, and if none arrives it tries twice more before locking the unit out completely rather than grinding the starter indefinitely. Unlike a warning that lets the generator keep running, Over Crank is a full shutdown: the display shows the fault, the unit won't attempt another start on its own, and it stays that way until someone clears it at the panel. The fault itself doesn't explain why the engine didn't catch — it only reports that three attempts failed — so real diagnosis starts with the two things most likely to keep any engine from firing at all: fuel and battery.
Most common causes
Kohler and most field technicians narrow this down to the same handful of culprits:
- Fuel supply issue (closed LP/NG valve, empty tank, or stale gasoline on portable/older models)
- Weak starting battery
- Fouled spark plug(s) or ignition fault
- Clogged fuel filter or carburetor issue
What you can check yourself
Work through these before touching anything else:
- Verify the fuel valve is open and there's adequate LP/NG supply or fresh fuel
- Check battery voltage and terminal connections
- Press the controller's AUTO button to clear the fault after correcting fuel/battery, then attempt a start
Pay attention to how the engine cranks while you're troubleshooting: a strong, fast crank that just won't catch points toward fuel or spark, while a slow, labored crank points straight back at the battery.